131All You Need Genomics
Electroporation
Electroporators, Cuvettes & Accessories
Description Pk Cat. No.
In vivo
Genetrode™, straight, 5 mm* 1 732-0010
In vivo
Genetrode™, straight, 10 mm* 1 732-0011
I
novo
G
enetrode™, bent L-shaped, 5 mm* 1
7
32-0012
In ovo
Genetrode™, bent L-shaped, 3 mm* 1 732-0013
In ovo
Genetrode™, bent L-shaped, 1 mm* 1 732-0014
Description Pk Cat. No.
Genepaddles, 5×7 mm paddles* 1
732-0032
Genepaddles, 3×5 mm paddles* 1 732-0950
Accessories
Description Pk Cat. No.
Genetrode/Genepaddle holder 1
732-0028
Accessories
Description Pk Cat. No.
Genetrode/Genepaddle holder 1
732-0028
Electrodes, Genetrodes™
Electrodes, Genepaddles
Electrodes, Tweezertrodes™
BTX
BTX
BTX
Genetrodes™ are paired, reusable, needle style electrodes that are ideal for
in vivo
and
in ovo
electroporation applications, including drug and gene delivery.
Genepaddles are non invasive, paddle-style, reusable electrodes designed for
in vivo
and
in
vitro
applications, such as gene delivery (IVEGD) in mouse embryos. The electrodes are
placed anterior and posterior to the embryo following injection of the molecule of interest, and
an electroporation pulse is delivered.
Tweezertrodes™ are reusable, tweezer style electrodes for
in vivo
drug or gene delivery
applications. Tweezertrodes™ consist of a standard 11,5 cm long tweezer modified with
stainless steel circular disc electrodes inserted at the tip. Following injection of the molecule of
interest, the electrode discs grasp the target tissue and an electroporation pulse is delivered,
initiating pore formation and incorporation of the molecules into the tissue cells that are in
direct contact with the electrode.
Five models to suit the size and shape of the target electroporation area
Each model consists of a pair of electrodes configured as either straight or bent L-shaped
electrodes with gold tips
The electrodes are placed into tissue following injection of the molecule of interest, and an
electroporation pulse is delivered using an electroporation generator
The electric field introduced by the Genetrodes™ causes transient pores to form in the cells
of the tissue, allowing uptake of the molecules into cells
Genetrodes™ are positioned in parallel at a predetermined gap in tissue using the
Genetrode/Genepaddle Holder
Gold plated rectangular paddles, available in two sizes 3×5 mm or 5×7 mm
Genepaddles may be positioned in parallel at a predetermined gap in tissue using the
Genetrode/Genepaddle Holder
The gap between the electrodes may be adjusted up to 2 cm and have a positive electrode
indicator
Choice of 7 mm or 10 mm diameter electrode
Platinum Tweezertrodes™ are also available, please enquire for further details
Generator compatibility: ECM 830, ECM 2001
Generator compatibility: ECM 830, ECM 2001
Voltage range: 0 - 200 V DC
Voltage range: 0 - 200 V DC (do not use AC)
Pulse length range: 10 µsec to 99 msec in PBS
Pulse length range: 10 µsec to 99 msec in PBS
Pulse number range: 1 - 99 (depending on voltage and pulse length settings)
Pulse number range: 1 - 99 (depending on voltage and pulse length settings)
Genetrode™ holder electrode gap: 1 - 10 mm range
Genetrode™ holder electrode gap: 1 - 10 mm range
* Requires Genetrodes/Genepaddle holder, square post cables and coaxial banana plug cable