VWR International 1325F Manuel d'utilisateur Page 87

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 144
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 86
85All You Need Genomics
Real Time PCR
SYBR Green qPCR
dR/dT
0.3
0.6
0.9
1.2
1.5
1.8
2.1
8580757065
90
Temperature (°C)
Fluorescence (norm)
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
4 8 12 16 20 24 28 32 36 40
Cycle number
B
Derivative reporter (-Rn)
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
8580757065
90
Temperature (°C)
Δ
Rn
Cycle number
0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
48
12 16 20
24
28 32 36 40
A
Description Pk Cat. No.
Maxima® SYBR Green qPCR master mix (2X), 2×1,25 ml (for 200 reactions of 25 µl), with ROX (50 µl) and 2×1,25 ml nuclease-free
water
2,5 ml
FERMK0251
Maxima® SYBR Green qPCR master mix (2X), 10×1,25 ml (for 1000 reactions of 25 µl), with ROX (250 µl) and 10×1,25 ml nuclease-
free water
12,5 ml
FERMK0252
Maxima® SYBR Green qPCR master mix (2X), 4×12,5 ml (for 4000 reactions of 25 µl), with ROX (1 ml) and 2×30 ml nuclease-free
water
1
FERMK0253
Maxima™ SYBR® Green qPCR master mix (2X), with ROX, Fermentas
Thermo Scientific
The Maxima™ SYBR Green qPCR master mix (2X) is a ready to use solution optimised for quantitative real time PCR and two-step real time
RT-PCR on most real time PCR machines. The master mix includes Maxima™ Hot Start
Taq
DNA polymerase, SYBR® Green dye I and
dNTPs in an optimised PCR buffer. ROX solution is provided in a separate vial for use with machines that require ROX as a passive reference
dye. Maxima™ Hot Start
Taq
DNA polymerase in combination with the optimised buffer ensures PCR specificity and sensitivity. The SYBR®
Green I intercalating dye allows for DNA detection and analysis without using sequence specific probes. dUTP is included in the mix for
optional carryover contamination control using uracil-DNA glycosylase (UDG). The use of Maxima™ SYBR Green qPCR master mix (2X) in
real time PCR ensures reproducible, sensitive and specific quantification of genomic, plasmid, viral and cDNA templates.
Specificity eliminates non specific amplification and formation of primer dimers
Sensitivity detects low copy number targets
ROX solution provided in a separate tube
Wide linear range accurate quantification across 9 orders of magnitude
Can be used on most real time PCR instruments
Ready to use
Delivery information: Supplied with 50 µM ROX solution and nuclease-free water.